Technical Buyer Guide

Pogo-Pin Working Travel and Board Tolerance Checks for Buyers

Compare pogo-pin working heights, calculate board-gap limits, check pad alignment and specify force, current and acceptance evidence before approving a connector.

Published by SINAWATTS · Last reviewed 18 November 2026 · Editorial and source policy

Approve a pogo-pin contact against the smallest and largest assembled gap at its own location, the complete pad-alignment envelope and the load conditions for the specified order code. A nominal working height describes one position. Procurement needs evidence that every accepted assembly keeps each spring contact within its permitted operating range while the mechanism holds the boards together.

This matters in charging docks, removable electronics, serviceable sensor assemblies and fixtures where a spring-loaded contact lands on a conductive surface. A sample can connect successfully at the center of its travel even though a production unit with a slightly different spacer, board bow or seating condition reaches a limit. Increasing the spring force might improve one symptom while making the housing deflect more. The quotation should identify these linked mechanical and electrical decisions before a purchase order fixes a component.

This guide uses a documented Harwin comparison and explicitly hypothetical assembly examples. The numerical examples explain screening methods. They are not SINAWATTS test results, a qualified design or evidence that an alternative component is interchangeable. No stock, manufacturing capability or delivery commitment follows from the examples.

Establish the reference surfaces and the meaning of travel

A pogo pin contains a movable contact member that compresses as the mating surface approaches. The useful procurement question is the height that remains in the closed assembly. Ask the designer to draw the supplier's height reference next to the installed mounting reference. A height measured from the contact's mounting plane cannot automatically be compared with a distance measured between two bare laminate surfaces.

Three descriptions often appear together. Free height is the uncompressed dimension. Working height describes the compressed position at which the manufacturer intends the contact to operate. Working range is the permitted interval when the supplier gives upper and lower operating limits. A separate mechanical travel or bottoming dimension may describe physical movement beyond that interval. Obtain the manufacturer's definitions before treating any travel number as usable design allowance.

State the height direction explicitly. A larger closed gap generally means less compression for the same contact. A smaller gap means more compression. Naming the low-gap condition the “minimum stroke” can therefore reverse the intended acceptance rule. Write both the physical dimension and its meaning in the review record, such as smallest installed gap and greatest compression.

Harwin describes P70-1000045R as an individual vertical SMT contact with a 3.5 mm free height and 2.9 mm working height. It also identifies a spherical head with a 0.9 mm diameter. Those figures describe that order code and its stated mounting arrangement. A buyer still needs the applicable drawing and installed references to transfer them into a board assembly. Harwin P70-1000045R product information

Record whether the target is a PCB pad, a separate contact pad, a metal insert or another qualified mating surface. Include any coating, plating or solder feature that changes the contact elevation. The drawing should show the surface that actually meets the plunger rather than a convenient nearby plane. A finish change belongs in the design review even when the nominal board spacing remains unchanged.

For assemblies using conventional two-piece board connectors, the related contact wipe and board-stack guide addresses their mating overlap. A spring contact landing on a pad needs the additional compression and landing checks developed here. Keep those acceptance drawings separate so that a reviewer cannot accidentally transfer a limit between mechanisms.

Compare two contacts with the same normal working height

Harwin's comparison chart lists the following dimensions and spring-force figures for two order codes. The chart is a screening reference, and the full component documents remain necessary for approval.

On small screens, swipe or scroll sideways to read every column. Keyboard users can focus the table and use the arrow keys.

Published characteristicP70-1000045RP70-2000045R
Free height3.5 mm3.6 mm
Maximum working height3.0 mm3.1 mm
Normal working height2.9 mm2.9 mm
Minimum working height2.7 mm2.85 mm
Listed spring force0.88 N1.27 N
Location peg shownNoYes

The matching normal height does not establish a matching operating envelope. The chart also identifies different force and locating arrangements. Keep the complete part suffix on the drawing and request the applicable force conditions and mounting details before considering substitution. Harwin pogo-pin comparison chart

Build the quote comparison around approval questions. Can the offered component accommodate the actual gap distribution? Does its position depend on a locating feature, solder joint or separate carrier? Will a higher reaction load change enclosure deflection? Does the assembly operation control the component's vertical position as assumed? An answer to one question does not close the others.

Procurement should also identify the party responsible for adapting the PCB footprint. A physically similar contact might need a different land pattern, hole or handling feature. Ask whether the supplier is offering the named manufacturer part, an explicitly proposed alternative or a custom assembly that contains it. These are different commercial scopes and need different evidence.

If an offered drawing changes a reference surface, annotate the comparison before circulating it. Reviewers should be able to trace each quoted dimension to an installed condition. A small redrawn sectional view with signed dimensions can prevent a larger mistake than a long list of nominal catalogue attributes.

Calculate the local gap envelope before accepting a sample

The following is a hypothetical screening calculation. It assumes that the contact's working-height reference has already been translated correctly into the assembly drawing. The chosen tolerances are invented to demonstrate the method. They are not measured production variation.

Suppose the intended local closed gap is 2.88 mm. The designer identifies three independent contributors whose signed extremes can each change that gap.

On small screens, swipe or scroll sideways to read every column. Keyboard users can focus the table and use the arrow keys.

Assumed contributor at the contactPossible gap change
Spacer dimension±0.04 mm
Board seating relative to its datum±0.03 mm
Local board flatness contribution±0.03 mm
Worst-case arithmetic total±0.10 mm

The simple bounded result is 2.78 mm to 2.98 mm. It deliberately adds the extremes. It does not assume a statistical distribution or a probability that the extremes occur together. Statistical tolerancing would require a justified model, process data and an agreed escape risk. A procurement spreadsheet should label whichever method it uses.

Against the published working-height intervals above, this hypothetical range fits inside the P70-1000045R interval, with only 0.02 mm remaining at its larger-gap end. It extends below the P70-2000045R minimum. That observation is a dimensional screen only. The small remaining margin may be unacceptable once the engineering team includes operating movement, measurement uncertainty or a required design reserve.

Do not silently use the remaining space as a vibration or wear allowance. List each additional contributor and decide where it enters the drawing. Thermal distortion, latch compliance and enclosure movement may depend on operating conditions rather than the manufactured dimensions measured during receiving inspection. Keep those conditions visible in the approval record.

A multi-contact assembly needs this calculation at more than one location. If a lid tilts, one corner can experience reduced compression while another experiences increased compression. A single central gap measurement will miss that combination. Mark the extreme contact locations and ask the designer to bound the local planes or surface profile.

Distinguish board thickness from board-surface position. A board mounted against a controlled top-side shoulder may transfer thickness variation differently from a board supported from underneath. Counting the same variation twice inflates the tolerance estimate. Omitting it because a board has a nominal thickness can make the estimate too optimistic. The drawing's datum chain decides which contribution applies.

Before the quotation is accepted, the responsible engineer should close a short decision record containing the reference surfaces, local minimum and maximum gaps, relevant operating states, required reserve and chosen component revision. Procurement can then ask vendors to respond to the same envelope instead of comparing unrelated nominal heights.

For an assembly enquiry, send the local gap drawing and target contact count to SINAWATTS. Include the permitted operating interval and any unresolved assumptions so the response can distinguish a documented component option from a design item that still requires confirmation.

Treat compression force as an assembly load

Every compressed contact pushes back on its mating structure. A high contact count can make that reaction significant even when the individual spring seems light. The latch, fasteners, board supports and housing carry the combined load. A dimensional check made before that load is applied may not describe the closed assembly.

Start the force budget with the manufacturer's force-versus-position information for the exact component. If only a nominal point is available, request the force tolerance at that point and the relevant curves or limits over the approved operating range. Mark the missing information as unresolved. Do not infer a spring rate from two catalogue heights or assume that force remains constant throughout travel.

As a separate hypothetical arithmetic illustration, eight contacts that each exert an assumed 1.0 N at a specified closed position produce 8.0 N of axial reaction before other loads are added. The 1.0 N value is invented and is not a rating for either Harwin example. This multiplication helps identify the load path. It does not establish a latch rating or a user operating force.

The actual mechanism can introduce leverage, seals, friction and off-axis loading. Closure force measured at a handle may therefore differ from the direct sum at the contacts. Tell the reviewer where the force is measured, at what movement rate and with which supporting parts present. The connector mating-force acceptance guide provides a broader method for controlling such measurements.

Keep the stopping function explicit. Ask the mechanical designer which feature establishes the final closed position and how it prevents excessive compression under the permitted user or fixture load. A component should not become an accidental travel stop merely because its plunger can physically move farther than the approved working position. Any unusual stop function needs component-specific manufacturer support.

Review board support as well as the latch. A flexible board can move away under spring load, reducing the compression that a rigid drawing predicts. Tightening a fastener can change that deflection and alter adjacent contacts. Request a representative assembled measurement or an engineering analysis appropriate to the risk, including the intended screw sequence and support arrangement when relevant.

A successful prototype closure is useful evidence only when its dimensions and force conditions are known. Record which contact positions were measured and how the fixture relates to the production structure. Otherwise a comfortable hand-operated sample can conceal an uncontrolled tolerance problem.

Verify where every plunger lands on its pad

Vertical travel and lateral alignment are separate acceptance questions. A contact can be comfortably within its working height while its tip approaches a pad edge, a solder-mask feature or the wrong conductor. Plot the permitted relative location of the contact head and the mating target in both board axes.

For a PCB assembly, possible contributors include component placement, pad position, board-to-housing location, locating-hole clearance and movement after the latch closes. Rotation can make the corner contact the worst case even when the center contacts remain aligned. Start from the actual locating features and avoid assuming that two boards share an origin because their drawings use similar coordinates.

Use a hypothetical geometry screen to make the issue visible. Assume a usable circular target 1.50 mm in diameter and a circular projected contact-head envelope 0.90 mm in diameter. Requiring the whole projected envelope to remain inside that target leaves a maximum center offset of 0.30 mm. If the bounded X and Y offsets are each 0.20 mm, the corner offset is about 0.283 mm, leaving roughly 0.017 mm in this simplified check.

This example assumes exact circles and does not include diameter tolerances, surface defects or movement during use. It is a conservative full-envelope construction, not a prediction of the real electrical contact patch of a spherical head. Have the designer define the required landing criterion and reserve. A calculation with a small positive result is not sufficient evidence of reliable contact.

Show the electrically usable target area separately from the artwork outline. Solder-mask encroachment, exposed edges, a raised solder deposit or a nearby component may reduce the practical landing space. The RFQ should carry the approved mating-surface drawing and finish specification, including who controls those features.

Explain how the assembly approaches the pad. A sliding or angled insertion can drag the tip before reaching its final position. That movement may create side loading or a wear path that a straight vertical compression test does not reproduce. Ask the manufacturer whether the proposed motion is supported, and qualify the actual mechanism where the answer depends on its geometry.

Procurement can request a marked inspection image showing the contact-center positions and usable pad boundaries on a representative assembly. Specify the datum and measurement method. An unscaled photograph is helpful for orientation but cannot close a dimensional acceptance requirement.

Keep current, heating and contact resistance tied to the installed state

Harwin's P70-1000045R product page lists a 2 A current rating. That component-specific value is a starting point for an application review. The buyer still needs the conditions relevant to compression, ambient environment, board conductors and neighboring loaded contacts. A listed maximum should not be multiplied across an array and presented as the demonstrated capability of a finished dock. Harwin P70-1000045R electrical information

Draw the supply and return paths. If a current flows through one outgoing contact and one return contact, both interfaces carry that current. If multiple contacts are intended to share a path, obtain the engineer's sharing assumptions and fault response. Nominally identical branches can have different resistance, so contact count alone does not establish an equal current split.

Request the applicable contact-resistance limits and measurement conditions. Useful details include where the measurement leads attach, how much fixture resistance is excluded, the compression position and whether the value is initial or after a specified conditioning sequence. Separate low-level signal evaluation from a powered heating test. The dry-circuit contact-resistance guide explains why the electrical stimulus belongs in the acceptance record.

A hypothetical heating calculation can show why resistance matters. At an assumed 1.5 A through an assumed 0.030 ohm interface resistance, I²R is 0.0675 W at that interface. Neither input is a measured value for the parts above. The calculation does not predict temperature because the thermal path and surroundings are unspecified. Its purpose is to show why the approved resistance and current conditions must be considered together.

For a densely loaded array, request evidence for the relevant population of active contacts and the intended enclosure. The loaded-contact current-derating guide helps define that question. Keep test conditions and observed results attached to the exact construction rather than transferring them from a mechanically similar sample.

If the design includes contact while energized, sequencing, arcing exposure or accessible conductors, have the responsible engineer define the application and protective measures. A spring-loaded contact rating does not by itself establish suitability for every energized mating arrangement. Procurement should obtain a documented answer before representing the assembly as approved for that use.

Build qualification evidence around the actual motion

Create a short evidence matrix that connects each application concern to an acceptance method. The owner should be clear. The component manufacturer supplies component documentation. The assembly designer approves installed limits. The selected test provider performs only the agreed tests within its confirmed scope. A quotation should not imply that SINAWATTS or any other party already has an unverified capability.

On small screens, swipe or scroll sideways to read every column. Keyboard users can focus the table and use the arrow keys.

ConcernEvidence to requestAcceptance decision
Gap extremesDrawing analysis and measured local gapsAll identified operating positions meet approved limits
Pad alignmentDatum-based position and usable-area measurementsLanding criterion holds at the identified extremes
Closure loadForce at defined location and closed conditionMechanism and supports remain within approved limits
Electrical contactSpecified resistance and continuity recordsResults meet the engineering limits under stated conditions
Repeated operationAgreed motion, condition and inspection sequencePerformance remains within the defined end-of-test limits

Set acceptance limits before the test begins. “Passed endurance” has little value without the movement, compression, environment and end criteria. Ask whether the sample used the intended pad finish and insertion path. A repeated axial motion in a laboratory fixture may provide component evidence while leaving the finished docking motion unresolved.

Match the monitored behavior to the application. A brief contact interruption can matter to a signal even when a resistance reading taken after motion looks acceptable. If interruption monitoring is required, define the electrical circuit, event threshold and observation method through the responsible engineering team. The vibration discontinuity guide covers that evidence boundary in more detail.

Keep the inspection sequence intentional. A dimensional inspection after disassembly may change the condition that caused the issue. Agree which measurements occur in the assembled state, which require opening the enclosure and whether inspection consumes or alters the sample. This helps avoid conflicting conclusions from two laboratories examining different states.

Use the resulting evidence to define production controls. A successful qualification build does not automatically establish a repeatable placement or assembly process. Identify which dimensions are checked routinely, which are controlled through process settings and which trigger requalification after a change. Record the treatment of incomplete or ambiguous inspection evidence before accepting a shipment.

Prepare an RFQ that separates the component from the assembly

Begin the RFQ with a single page containing the application, order-code requirement, contact count, local gap envelope and mating-target drawing. Attach the detailed calculations and evidence requests separately. A vendor should be able to understand the requested decision before reading the complete mechanical package.

Specify the purchase scope in ordinary terms. It may be loose contacts, contacts assembled to a PCB, a carrier populated with contacts or a finished interconnect assembly. Identify who supplies the mating board and who is responsible for the pad finish. Mention any customer-supplied part or drawing that changes the acceptance boundary.

Use the SINAWATTS OEM/ODM service enquiry to describe the assembly scope that needs review. Availability of a particular process, tooling route or inspection service requires written confirmation for the project. An enquiry link does not establish that a proposed custom construction has already been qualified.

Ask suppliers to return a controlled response with the exact offered manufacturer and part suffix, drawing revision, exceptions, source documents and proposed evidence. For an alternative, request a difference list covering working envelope, force, mounting, tip geometry, electrical conditions and process compatibility. A declaration of “equivalent” should not replace that comparison.

Commercial details should follow the technical scope. Request the quantity basis, sample arrangement, packaging, tooling ownership if applicable, inspection deliverables and proposed schedule. Quote validity and delivery depend on the actual offer. Avoid treating an older catalogue page or previous purchase as confirmation of present stock, price or lead time.

Agree which changes require notification. Relevant changes can include the contact order code, pad finish, component placement process, support structure or closed-stop dimension. A change that leaves the external outline unchanged may still alter compression or landing. Tie the notification requirement to the approved drawings and evidence rather than an informal product name.

Once the engineering limits and responsibilities are clear, send the controlled pogo-pin RFQ package to SINAWATTS. Include the intended mating motion, loading conditions, quantity range and open technical questions. That gives the receiving team a useful basis for confirming scope and requesting missing evidence.

Buyer FAQ

Can two pogo pins with the same working height be substituted?

A shared nominal height is only one comparison point. Check the full working interval, locating features, mounting drawing, force conditions, tip geometry and electrical evidence. The two order-code examples in this guide demonstrate why the interval matters. The responsible engineer should approve the complete difference list before procurement changes the specified component.

Is the maximum mechanical travel available for normal operation?

Use the manufacturer's stated operating limits and definitions. A physical travel limit can describe a position that the supplier has not approved for repeated electrical service. Ask for clarification when a drawing shows only a free height and an end position. Keep the allowed operating interval explicitly stated on the assembly acceptance drawing.

How many tolerance contributors should be included?

Include every contributor that can move the actual contact and target relative to their approved references. Start with the datum chain, then consider operating movement and measurement uncertainty. Avoid counting the same effect twice. A designer should review the contributors because the mounting arrangement determines whether a particular board or enclosure tolerance changes the local gap.

Does a stronger spring guarantee more reliable contact?

Force is one part of the interface. Increasing it also changes loads on the latch, board and support structure. That can alter the installed position. Ask for the specified force range and relevant electrical evidence, then qualify the complete mechanism. Do not replace a controlled landing surface or an unresolved tolerance problem with an arbitrary increase in force.

Can the current rating be added across parallel contacts?

Only use a combined rating supported by the approved design and evidence. The current may not divide equally between contacts, and the return path has its own limits. Define the number of loaded contacts, branch resistance assumptions, environment and relevant fault behavior. A component's published number does not demonstrate the capacity of the assembled parallel path.

What evidence is useful when a supplier has no force curve?

Ask first for the manufacturer's applicable specification or written limits at the required operating positions. If those remain unavailable, the engineering team must decide whether a controlled measurement and qualification plan can resolve the gap. Procurement should keep the item open until that decision is documented instead of estimating a curve from nominal dimensions.

Should every production assembly undergo an endurance test?

Define production inspection separately from design qualification. An endurance test may alter a sample and may not be suitable for every shipped unit. The engineering and quality teams should agree routine checks, sampling and change triggers based on the application risk. Record what is measured and how acceptance is decided rather than prescribing an unsupported universal sampling rule.

What should be sent first to obtain a useful quotation?

Send the contact arrangement, exact order code if fixed, local gap limits, mating-pad drawing and intended motion. Add electrical loading, quantity range and requested evidence. Mark unresolved items clearly. The supplier can then identify whether it can quote the specified scope and which technical or commercial conditions need confirmation before an offer becomes actionable.