Buy a reed sensor as a defined combination of switch, actuator magnet, mounting geometry and electrical load. An ampere-turn sensitivity band does not by itself guarantee a switching distance in your enclosure, and carrying current does not establish the current that contacts may safely make or break. Those two distinctions should appear explicitly in the request for quotation.
A magnetic position signal can look simple: two wires change state when a magnet moves. Procurement problems arise when a replacement sensor has a familiar housing but a different magnetic response, when a stronger magnet prevents timely release, or when a contact suitable for a controller input is asked to switch a load directly. A continuity check at the packing bench can miss all three problems.
This guide explains how to compare offers without inventing a universal sensing gap or treating a component rating as approval of a complete machine. Manufacturer data below are named examples. Worked calculations use hypothetical application requirements, not customer results or SINAWATTS test data. The purchasing deliverable is a reproducible assembly specification and an evidence list that the responsible engineer can approve.
Define the state that the equipment actually needs
Start with the physical positions and the corresponding electrical states. For a simple normally open contact, describe what should happen when the defined magnet is absent, approaching, within the closed-position envelope, retreating and fully away. If a quotation says normally closed, require the vendor to identify the exact contact arrangement and any bias magnet involved. Do not assume two products use the same internal construction because their output descriptions match.
For a changeover arrangement, name the common terminal and both branches. Write a terminal-to-terminal state table rather than relying on wire color or the word “closed.” A door can be mechanically closed while the specified electrical contact is open; that language collision is avoidable if the drawing labels both states separately.
The application owner should also define the response to a missing magnet, a broken wire and a shorted cable. A plain reed contact does not inherently distinguish every one of these conditions. If fault diagnosis or a safety-related interlock is required, the responsible system designer must specify the architecture and supporting evidence. Do not infer a safety function from a magnet symbol or a contact rating.
Record whether the controller expects a sustained level, an edge or a pulse, and whether a brief transition is acceptable. This prevents a supplier from delivering a device that changes state correctly on a static fixture but produces an unsuitable signal during the real movement.
Keep ampere-turn sensitivity attached to its test method
Ampere-turns, commonly written AT, describe a coil excitation used to characterize magnetic operation. In its test-coil guidance, Standex Detect explains that manufacturers use different test coils and that sensitivity is normally specified for an uncut, unbent switch. Cutting or bending leads can change the result. An AT figure therefore needs its manufacturer, coil method and physical lead condition.
For purchasing, separate three records: the bare switch sensitivity classification, the finished sensor's response with its nominated magnet, and the installed assembly's accepted positional window. These records answer different questions. A narrow incoming AT band can help control a component while still leaving the final enclosure geometry unresolved.
Ask whether the offered sensitivity code refers to operate, release, a combination of limits or a catalog sorting band. Record the specified temperature and any required magnetic conditioning. If two suppliers quote the same AT numbers under different methods, treat equivalence as unproven until the engineer has a valid comparison.
Avoid translating AT directly into millimeters using a generic calculator. The field at the contact depends on the actuator and geometry, and the finished sensor can include materials or lead arrangements absent from the bare-switch fixture. A supplier's distance measurement is more useful when the exact magnet, motion path, datum and measurement method accompany it.
If a proposed substitute changes lead length or the molded package, ask which qualification evidence remains applicable. Reusing the old sensitivity label is not a sufficient explanation.
Freeze the magnet and motion path before selecting a distance
The actuator belongs in the controlled bill of materials. Identify its manufacturer and part number where available, dimensions, magnetization direction, orientation marks and assembly retention method. For a custom actuator, request the supplier's controlled specification and the evidence used to establish consistency. Do not select a magnet solely from a photograph or an unverified material description.
Standex Detect's activation-distance guide illustrates different magnet orientations and motion paths, and describes its tabulated distances as typical values that can vary with application conditions. Use such guidance to prepare a fixture; do not turn a typical catalog distance into a guaranteed production limit.
A usable drawing identifies the sensor reference face, magnet reference face, direction of travel and permitted rotation. Show nearby brackets, fasteners and other magnetic components where the engineer considers them relevant. Test the intended arrangement rather than approving a loose sensor and magnet held together by hand.
For a hinged mechanism, specify the angular travel and the resulting path through the switching region. A single perpendicular gap can fail to describe a magnet moving past one end of a sensor. For sliding motion, identify lateral offset and the full travel, including any region where an extra transition would be unacceptable.
Request both approach and retreat observations. A longer activation distance is not automatically better if the system needs a definite release at an intermediate position. Define the useful operating window first, then select an actuator and sensor that meet it with appropriate tolerances.
Compare the complete operate and release window
The following example is an invented purchasing screen for a simple monotonic approach-and-retreat path. It is not a claim about a catalog part, a measured sample or a universal magnetic law.
Assume the drawing already accounts for the mechanism's dimensional tolerances. At the required closed position, the largest allowed sensor-to-magnet gap is 5 mm. At the required open position, the smallest allowed gap is 14 mm. The engineer requires the contact to be closed at every permitted closed position and open at every permitted open position.
The quoted assembly guarantees must cover the nominated magnet, orientation, temperature range and production variation. A smallest guaranteed operate distance of at least 5 mm supports closure by the largest closed gap. A largest guaranteed release distance no greater than 14 mm supports release by the smallest open gap.
On small screens, swipe or scroll sideways to read every column. Keyboard users can focus the table and use the arrow keys.
| Hypothetical quotation | Smallest guaranteed operate distance | Largest guaranteed release distance | Initial positional decision |
|---|---|---|---|
| Assembly A | 6 mm | 13 mm | Passes this limited window screen with 1 mm at each boundary |
| Assembly B | 4 mm | 15 mm | Does not guarantee closure at 5 mm or release by 14 mm |
| Assembly C | Typical 7 mm only | Not supplied | Insufficient evidence for either production boundary |
The 1 mm differences in Assembly A are arithmetic margins, not a conclusion that the design is robust. The engineer still has to decide whether the guarantees include all relevant temperature, alignment, wear and mounting variations, and whether measurement uncertainty leaves enough margin. If any variation is excluded, add it to the assessment rather than quietly consuming the stated gap.
Define how uncertain or borderline readings are handled before inspection. A convenient hand measurement is not a substitute for an agreed datum and a decision rule.
Send the sensor drawing, magnet identity and required position window for an RFQ discussion. Include the load description as well; a mechanically acceptable switch can still be electrically unsuitable.
Separate switching current, carrying current and switching power
The Littelfuse 59140 data sheet, revision GD dated September 20, 2023, provides a useful comparison. Its Type 1 normally open and Type 3 changeover versions have different maximum DC ratings:
On small screens, swipe or scroll sideways to read every column. Keyboard users can focus the table and use the arrow keys.
| Listed maximum | Type 1 normally open | Type 3 changeover |
|---|---|---|
| Switching power | 10 W | 5 W |
| Switching voltage | 200 V DC | 175 V DC |
| Switching current | 0.5 A DC | 0.25 A DC |
| Carrying current | 1.2 A DC | 1.5 A DC |
The manufacturer's notes require switched voltage multiplied by switched current to remain within the maximum power, and warn that inductive or capacitive loads need transient consideration. These are component-specific published values, not SINAWATTS product specifications or a recommendation for a particular installation.
The comparison exposes an easy buying mistake: Type 3 has the higher carrying-current number but the lower switching-current and switching-power limits. Selecting only the largest current in the table would reverse the useful conclusion for a contact that must interrupt a load.
For a hypothetical 24 V DC resistive circuit drawing 0.30 A, the simple product is 7.2 W. Type 1 passes those basic published voltage, current and power screens. Type 3 fails the 0.25 A and 5 W screens despite its higher carrying rating. This does not approve Type 1 for an application or establish endurance; load behavior, temperature and the manufacturer's complete conditions remain relevant.
A second hypothetical load of 24 V at 0.50 A gives 12 W. It reaches Type 1's current limit but exceeds its 10 W power limit. Maximum ratings cannot be treated as values that are always simultaneously usable. Ask for an application-specific permitted operating envelope when the rating table does not fully answer the question.
Describe the load at contact make and break
The electrical schedule should identify the circuit connected to the contact, not simply say “24 V sensor.” Distinguish a controller input, a relay coil, a lamp, a capacitive input and another load. Give the normal voltage range, steady current, switching frequency and relevant startup or shutdown conditions. State which side of the circuit is switched and whether either wire can receive a different potential during a fault.
In its handling and load precautions, Standex Detect discusses capacitive inrush, including cable capacitance, and overvoltage when inductive loads open. It also explains that unsupported lead forming can damage a reed's seal or alter performance. These cautions support asking for both electrical load evidence and assembly-process control.
Do not choose a contact-protection circuit from a generic sketch without an engineering review. Suppression can affect the load's release behavior or signal timing, and its placement belongs on the circuit drawing. If the engineer chooses an electronic interface so that the reed only operates an input, qualify the entire interface and its failure behavior.
For a low-level input, provide the input's actual source voltage and current, accepted resistance range, leakage behavior and logic thresholds. Ask for evidence at that load rather than assuming a high power rating proves reliable detection of small signals. The separate [low-level contact resistance guide](/blog/connector-low-level-contact-resistance-dry-circuit-acceptance-rfq-guide.html) explains why measurement conditions belong in an acceptance specification.
A vendor should identify whether its endurance evidence used a resistive load, a particular electronic input or another circuit. Results from a different load may inform selection, but the report must make that difference visible instead of presenting an unrelated cycle count as an application guarantee.
Control the sensor assembly and the cable exit
The supplied item may be a bare glass switch, a housed sensor with flying leads or a complete harness. Name the deliverable explicitly. Buying a component and buying a qualified assembly have different inspection boundaries; the quotation should show which supplier is responsible for mounting, lead forming, encapsulation, cable termination and final magnetic verification.
For a bare switch, request the manufacturer's permitted handling and lead-forming instructions before approving the assembly drawing. For a housed sensor, control how installation forces reach the housing and cable exit. Avoid assigning an arbitrary pull force or bend radius without the selected construction's requirements and the application's mechanical assessment.
Specify connector identity, contact positions and the view used for the pin map. A harness that passes continuity can still present the wrong state to a controller if common and changeover wires were assigned incorrectly. Use the [cavity-view and wire-identification guide](/blog/cable-harness-pinout-cavity-view-wire-identification-rfq-guide.html) when the sensor terminates in a multiway connector.
State the routing and restraint arrangement near the sensor. Service slack, repeated motion and installer access should be considered on the drawing, with acceptance evidence appropriate to the use. The [strain-relief and bend-radius guide](/blog/cable-assembly-strain-relief-bend-radius-rfq-guide.html) helps separate cable routing requirements from a claim that a molded boot alone solves every mechanical issue.
A change to potting, a bracket or a cable exit should enter the change-review process if it can affect the controlled assembly. Procurement should ask the engineering owner which evidence must be repeated, rather than automatically accepting a cosmetically identical replacement.
Make the controller response part of qualification
A magnetic threshold and a controller decision are separate observations. Record the raw contact behavior and the signal accepted by the controller where relevant. Otherwise an input filter can conceal a problem during inspection, or a bench continuity indicator can miss a brief interruption that the application detects.
The responsible engineer should specify any debounce or filtering rule and the maximum permitted response delay. Procurement should not invent a universal debounce interval. The acceptable delay depends on the mechanism speed, how the signal is used and the consequence of a missed or delayed transition.
A practical qualification sequence names the assembly revision, verifies its terminal states, measures approach and retreat behavior on the agreed path, checks the intended electrical load, and observes the system response during the required movements. Environmental and endurance checks follow the approved application plan. This is a planning framework, not a claim that every application needs the same test suite.
Include a clear instruction for intermediate positions. Is the system allowed to retain its previous state there, or does the application require a particular indication? Without that decision, two teams can interpret the same operate/release behavior differently.
If the signal contributes to an interlock, keep the functional evidence separate from any formal safety assessment. The [auxiliary-contact and interlock guide](/blog/battery-disconnect-switch-auxiliary-contacts-interlocks-state-feedback-rfq-guide.html) offers related questions about state feedback, but it does not certify a reed-sensor arrangement.
Build evidence that survives supplier and lot changes
Ask for a report tied to the finished sensor identity, actuator identity and drawing revision. Record which samples were used and whether they represent a single lot or several lots. One carefully selected sample can demonstrate a measurement method; it cannot establish the whole production distribution without additional evidence.
A useful positional record shows the approach direction, retreat direction, mounting offsets, temperature and threshold readings. Include fixture revision and measurement uncertainty where these affect the acceptance boundary. Keep raw observations available for the engineering reviewer instead of reducing everything to a single green “pass.”
Separate qualification, routine production checks and incoming inspection. Qualification addresses the approved operating envelope. Routine checks control the delivered configuration. Incoming checks verify agreed characteristics using available equipment. A receiving team should not be expected to recreate an undefined manufacturer's magnetic test after goods arrive.
The purchase specification should require notification before changes to the switch, sensitivity band, magnet, lead treatment, housing, assembly process or relevant subcontracted operation. Name the person or function authorized to accept changes, the evidence needed and the treatment of stock already produced. Do not let “equivalent material” become an unrestricted substitution clause.
Where evidence is missing, list it as an open item with an owner and due point. Commercial comparison can continue, but final technical approval should wait for the particular gap to be resolved. This keeps negotiation moving without disguising uncertainty as compliance.
Prevent a correct sensor from being paired with the wrong actuator
Receiving inspection should identify the actuator separately from the sensor. When the two items arrive in different cartons or are installed by different teams, a matched qualification can be lost without either component looking defective. Require package references that connect both items to the approved assembly drawing, and define how the installer checks orientation before closing the enclosure.
A golden sample can help train operators, but it should not become an undocumented substitute for the acceptance specification. Record its identity and the conditions under which it is used. If a comparison fails, check the fixture, actuator and specimen before attributing the difference to the sensor alone.
For service replacements, keep the sensor and magnet revision in the equipment record. State whether a replacement is approved individually or only as a matched pair. If the installed actuator cannot be identified, the engineer should decide what verification is required before releasing the replacement. This is especially useful when a field technician can access the sensor easily but the magnet is embedded in another assembly. It turns an ambiguous spare-part request into a specific compatibility decision.
Send a quotation package suppliers can answer consistently
Prepare a compact package with five parts: the state table, the mechanical and magnetic drawing, the load schedule, the verification plan and the commercial delivery scope. Each part should carry a revision so a supplier's acceptance can be traced to the same requirements used for production.
Require a line-by-line response showing the proposed part, confirmed limits, exceptions and the document supporting each confirmation. Ask the vendor to distinguish guaranteed limits from typical values and engineering estimates. If a distance or load limit needs custom qualification, the response should say so and identify the proposed work.
Compare offers using unresolved technical risk as well as piece price. An offer with a fully identified actuator and a narrower documented operating window may be easier to approve than one advertising a long nominal sensing distance without release data. Conversely, do not pay for a tighter band that the application does not need; let the approved tolerance analysis establish value.
For an assembly discussion, the [OEM and ODM service page](/products/oem-odm-service.html) provides a route to describe the required integration. It does not confirm availability of a particular reed sensor, magnet, test fixture or qualification capability. Those items need explicit confirmation in the quotation.
Send the state table, load schedule and supplier exceptions for a sensor-assembly RFQ discussion. Include requested quantity and destination for commercial review, while keeping technical acceptance independent of any unconfirmed price, lead time or minimum order.
Buyer FAQ
Can the same AT band replace the same sensor part number?
Not by itself. The coil method, lead condition, contact arrangement and final actuator response must be comparable. Treat the AT band as one controlled characteristic. A replacement still needs evidence against the assembly drawing and its accepted operate/release window.
Is a stronger magnet always a safer choice?
No. It may help operation at one position while delaying release at another. Verify both directions of travel and the complete positional envelope. A stronger magnet is a proposed design change, not an automatic correction for an undefined gap requirement.
Can I switch a load using the carrying-current rating?
The carrying rating describes a different condition from making or breaking the circuit. Check switching voltage, switching current, switching power and the actual load behavior together. The published example above shows a version with higher carrying current but lower switching capacity.
Does a continuity test prove the finished sensor is acceptable?
It proves only what that test actually observes. A single closed-state reading does not establish release distance, switching endurance, response to alignment variation or controller timing. Specify the additional evidence needed for the intended use without claiming that every sensor needs identical tests.
Should I use typical activation distance as an incoming limit?
Only if the manufacturer and responsible engineer establish a valid acceptance requirement and method. A typical catalog figure is not automatically a guaranteed production boundary. Request the guaranteed window for the exact sensor, actuator, mounting arrangement and relevant conditions.
Can a normally closed reed contact diagnose a broken cable?
A plain contact circuit may not distinguish an open contact from an open cable. Diagnosis depends on the complete circuit and controller design. Ask the engineer to define fault detection and the permitted system response; do not infer it from the normally closed label.
What information should I send before requesting a sensor quotation?
Send the required states, motion drawing, nominated magnet, positional tolerances, electrical load, connector pin map and acceptance plan. Identify open decisions. A supplier can then quote a defined deliverable and expose exceptions rather than guessing from a nominal voltage and sensing distance.